Now showing items 1-1 of 1

    • Von Nimitz, Walter W. (Texas A&M University. Gas Turbine Laboratories, 1975)
      Low frequency vibrations at centrifugal compressor and pump installations are usually discarded as unlikely. However, severe acoustically excited vibrations at frequencies as low as 5 or 10 Hz have been observed at a number ...